CVE Severity Published▾ Status Exploitation Description
CVE-2025-41697 Medium 2025-12-09 Not applicable No public exploit An attacker can use an undocumented UART port on the PCB as a side-channel to get root access e.g. with the credentials obtained from CVE-2025-41692.
CVE-2025-41696 Medium 2025-12-09 Not applicable No public exploit An attacker can use an undocumented UART port on the PCB as a side-channel with the user hardcoded credentials obtained from CVE-2025-41692 to gain read access to parts of the filesystem of the device.
CVE-2025-41694 Medium 2025-12-09 Not applicable No public exploit A low privileged remote attacker can run the webshell with an empty command containing whitespace. The server will then block until it receives more data, resulting in a DoS condition of the websserver.
CVE-2025-41693 Medium 2025-12-09 Not applicable No public exploit A low privileged remote attacker can use the ssh feature to execute commands directly after login. The process stays open and uses resources which leads to a reduced performance of the management functions. Switching functionality is not affected.
CVE-2025-41692 Medium 2025-12-09 Not applicable No public exploit A high privileged remote attacker with admin privileges for the webUI can brute-force the "root" and "user" passwords of the underlying OS due to a weak password generation algorithm.
CVE-2025-24004 Medium 2025-07-08 Not applicable No public exploit A physical attacker with access to the device display via USB-C can send a message to the device which triggers an unsecure copy to a buffer resulting in loss of integrity and a temporary denial-of-service for the stations until they got restarted by the watchdog.
CVE-2025-24002 Medium 2025-07-08 Not applicable No public exploit An unauthenticated remote attacker can use MQTT messages to crash a service on charging stations complying with German Calibration Law, resulting in a temporary denial-of-service for these stations until they got restarted by the watchdog.
CVE-2024-7734 Medium 2024-09-10 Not applicable No public exploit An unauthenticated remote attacker can exploit the behavior of the pathfinder TCP encapsulation service by establishing a high number of TCP connections to the pathfinder TCP encapsulation service. The impact is limited to blocking of valid IPsec VPN peers.
CVE-2024-7698 Medium 2024-09-10 Not applicable No public exploit A low privileged remote attacker can get access to CSRF tokens of higher privileged users which can be abused to mount CSRF attacks.
CVE-2024-3913 Medium 2024-08-13 Not applicable No public exploit An unauthenticated remote attacker can use this vulnerability to change the device configuration due to a file writeable for short time after system startup.
CVE-2024-28135 Medium 2024-05-14 Not applicable No public exploit A low privileged remote attacker can use a command injection vulnerability in the API which performs remote code execution as the user-app user due to improper input validation. The confidentiality is partly affected.
CVE-2024-26005 Medium 2024-03-12 Not applicable No public exploit An unauthenticated remote attacker can gain service level privileges through an incomplete cleanup during service restart after a DoS. 
CVE-2024-25997 Medium 2024-03-12 Not applicable No public exploit An unauthenticated remote attacker can perform a log injection due to improper input validation. Only a certain log file is affected.
CVE-2024-25994 Medium 2024-03-12 Not applicable No public exploit An unauthenticated remote attacker can upload a arbitrary script file due to improper input validation. The upload destination is fixed and is write only.
CVE-2023-46144 Medium 2023-12-14 Not applicable No public exploit A download of code without integrity check vulnerability in PLCnext products allows an remote attacker with low privileges to compromise integrity on the affected engineering station and the connected devices.
CVE-2023-37858 Medium 2023-08-09 Not applicable No public exploit In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 an authenticated, remote attacker with admin privileges is able to read hardcoded cryptographic keys allowing to decrypt an encrypted web application login password.
CVE-2023-37856 Medium 2023-08-09 Not applicable No public exploit In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges is able to gain limited read-access to the device-filesystem through a configuration dialog within the embedded Qt browser .
CVE-2023-37855 Medium 2023-08-09 Not applicable No public exploit In PHOENIX CONTACTs WP 6xxx series web panels in versions prior to 4.0.10 a remote attacker with low privileges is able to gain limited read-access to the device-filesystem within the embedded Qt browser.
CVE-2023-3569 Medium 2023-08-08 Not applicable No public exploit In PHOENIX CONTACTs TC ROUTER and TC CLOUD CLIENT in versions prior to 2.07.2 as well as CLOUD CLIENT 1101T-TX/TX prior to 2.06.10 an authenticated remote attacker with admin privileges could upload a crafted XML file which causes a denial-of-service.
CVE-2023-2673 Medium 2023-06-13 Not applicable No public exploit Improper Input Validation vulnerability in PHOENIX CONTACT FL/TC MGUARD Family in multiple versions may allow UDP packets to bypass the filter rules and access the solely connected device behind the MGUARD which can be used for flooding attacks.
CVE-2021-34582 Medium 2021-11-10 Not applicable No public exploit In Phoenix Contact FL MGUARD 1102 and 1105 in Versions 1.4.0, 1.4.1 and 1.5.0 a user with high privileges can inject HTML code (XSS) through web-based management or the REST API with a manipulated certificate file.
CVE-2021-21003 Medium 2021-06-25 Not applicable No public exploit In Phoenix Contact FL SWITCH SMCS series products in multiple versions fragmented TCP-Packets may cause a Denial of Service of Web-, SNMP- and ICMP-Echo services. The switching functionality of the device is not affected.
CVE-2020-12521 Medium 2020-12-17 Not applicable No public exploit On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS a specially crafted LLDP packet may lead to a high system load in the PROFINET stack. An attacker can cause failure of system services or a complete reboot.
CVE-2020-12518 Medium 2020-12-17 Not applicable No public exploit On Phoenix Contact PLCnext Control Devices versions before 2021.0 LTS an attacker can use the knowledge gained by reading the insufficiently protected sensitive information to plan further attacks.
CVE-2019-10998 Medium 2019-06-18 Not applicable No public exploit An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity.
CVE-2019-10997 Medium 2019-06-17 Not applicable No public exploit An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell.
CVE-2018-13991 Medium 2019-05-07 Not applicable No public exploit The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 leaks private information in firmware images.
CVE-2018-10729 Medium 2018-05-17 Not applicable No public exploit All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 allow reading the configuration file by an unauthenticated user.
CVE-2017-16741 Medium 2018-01-12 Not applicable No public exploit An Information Exposure issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32. A remote unauthenticated attacker may be able to use Monitor Mode on the device to read diagnostic information.
CVE-2017-5753 Medium 2018-01-04 Not applicable Exploited Systems with microprocessors utilizing speculative execution and branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
CVE-2017-16723 Medium 2017-12-11 Not applicable No public exploit A Cross-site Scripting issue was discovered in PHOENIX CONTACT FL COMSERVER BASIC 232/422/485, FL COMSERVER UNI 232/422/485, FL COMSERVER BAS 232/422/485-T, FL COMSERVER UNI 232/422/485-T, FL COM SERVER RS232, FL COM SERVER RS485, and PSI-MODEM/ETH (running firmware versions prior to 1.99, 2.20, or 2.40). The cross-site scripting vulnerability has been identified, which may allow remote code execution.
CVE-2017-10198 Medium 2017-08-08 No exploit published No public exploit Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: Security). Supported versions that are affected are Java SE: 6u151, 7u141 and 8u131; Java SE Embedded: 8u131; JRockit: R28.3.14. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. While the vulnerability is in Java SE, Java SE Embedded, JRockit, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 6.8 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N).
CVE-2017-10135 Medium 2017-08-08 Protected by Waratek No public exploit Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: JCE). Supported versions that are affected are Java SE: 6u151, 7u141 and 8u131; Java SE Embedded: 8u131; JRockit: R28.3.14. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized access to critical data or complete access to all Java SE, Java SE Embedded, JRockit accessible data. Note: This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 5.9 (Confidentiality impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N).
CVE-2017-10108 Medium 2017-08-08 Protected by Waratek No public exploit Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: Serialization). Supported versions that are affected are Java SE: 6u151, 7u141 and 8u131; Java SE Embedded: 8u131; JRockit: R28.3.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized ability to cause a partial denial of service (partial DOS) of Java SE, Java SE Embedded, JRockit. Note: This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 5.3 (Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
CVE-2017-10053 Medium 2017-08-08 No exploit published No public exploit Vulnerability in the Java SE, Java SE Embedded, JRockit component of Oracle Java SE (subcomponent: 2D). Supported versions that are affected are Java SE: 6u151, 7u141 and 8u131; Java SE Embedded: 8u131; JRockit: R28.3.14. Easily exploitable vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded, JRockit. Successful attacks of this vulnerability can result in unauthorized ability to cause a partial denial of service (partial DOS) of Java SE, Java SE Embedded, JRockit. Note: This vulnerability can be exploited through sandboxed Java Web Start applications and sandboxed Java applets. It can also be exploited by supplying data to APIs in the specified Component without using sandboxed Java Web Start applications or sandboxed Java applets, such as through a web service. CVSS 3.0 Base Score 5.3 (Availability impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L).
CVE-2008-7199 Medium 2009-09-10 Not applicable No public exploit Phoenix Contact FL IL 24 BK-PAC allows remote attackers to cause a denial of service (hang) via (1) unspecified manipulations as demonstrated by a Nessus scan or (2) malformed input to TCP port 502.