Overview 53 matches · 0 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 2 public PoC · 0 EPSS ≥ 0.5
53matches
0in Waratek scope0.0%
0protected0.0%
0exploited0.0%
0CISA KEV0.0%
2public PoC3.8%
0EPSS ≥ 0.50.0%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
2
3.8%
Not applicable
51
96.2%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
53
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
2
3.8%
Proof of concept only
3
5.7%
Forecast only
0
0.0%
No public exploit
48
90.6%
split by
peak 13 / year
20011
Not applicable1
Low1
not blocked1
Working exploit published1
20020
20030
20041
Not applicable1
Low1
not blocked1
Working exploit published1
20050
20060
20070
20080
20090
20100
20110
20122
Not applicable2
Low2
not blocked2
No public exploit2
20131
Not applicable1
Low1
not blocked1
No public exploit1
20140
20159
Not applicable9
Low9
not blocked9
No public exploit9
20163
Not applicable3
Low3
not blocked3
No public exploit3
20170
20181
Not applicable1
Low1
not blocked1
No public exploit1
20191
Not applicable1
Low1
not blocked1
No public exploit1
20201
Not applicable1
Low1
not blocked1
Proof of concept only1
202113
Outside Waratek scope1
Not applicable12
Low13
not blocked13
Proof of concept only2
No public exploit11
20220
20238
Not applicable8
Low8
not blocked8
No public exploit8
20243
Not applicable3
Low3
not blocked3
No public exploit3
20259
Outside Waratek scope1
Not applicable8
Low9
not blocked9
No public exploit9
2001200320052007200920112013201520172019202120232025
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2025-40818 | Low | 2025-12-09 | Not applicable | No public exploit | A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2 SP4). Affected applications contain private SSL/TLS keys on the server that are not properly protected allowing any user with server access to read these keys. This could allow an authenticated attacker to impersonate the server potentially enabling man-in-the-middle, traffic decryption or unauthorized access to services that trust these certificates. |
| CVE-2025-40803 | Low | 2025-09-09 | Not applicable | No public exploit | A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device exposes certain non-critical information from the device. This could allow an unauthenticated attacker to access sensitive data, potentially leading to a breach of confidentiality. |
| CVE-2025-40802 | Low | 2025-09-09 | Not applicable | No public exploit | A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions). The affected device may be susceptible to resource exhaustion when subjected to high volumes of query requests. This could allow an attacker to cause a temporary denial of service, with the system recovering once the activity stops. |
| CVE-2024-41985 | Low | 2025-08-12 | Not applicable | No public exploit | A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application does not expire the session without logout. This could allow an attacker to get unauthorized access if the session is left idle. |
| CVE-2024-41984 | Low | 2025-08-12 | Not applicable | No public exploit | A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application improperly handles error while accessing an inaccessible resource leading to exposing the system applications. |
| CVE-2024-41980 | Low | 2025-08-12 | Not applicable | No public exploit | A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application do not encrypt the communication in LDAP interface by default. This could allow an authenticated attacker to gain unauthorized access to sensitive information. |
| CVE-2025-8732 | Low | 2025-08-08 | Not applicable | No public exploit | A vulnerability was found in libxml2 up to 2.14.5. It has been declared as problematic. This vulnerability affects the function xmlParseSGMLCatalog of the component xmlcatalog. The manipulation leads to uncontrolled recursion. Attacking locally is a requirement. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. The code maintainer explains, that "[t]he issue can only be triggered with untrusted SGML catalogs and it makes absolutely no sense to use untrusted catalogs. I also doubt that anyone is still using SGML catalogs at all." |
| CVE-2025-27398 | Low | 2025-03-11 | Not applicable | No public exploit | A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths. This could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem. |
| CVE-2024-45385 | Low | 2025-01-14 | Outside Waratek scope | No public exploit | A vulnerability has been identified in Industrial Edge Management OS (IEM-OS) (All versions). Affected components are vulnerable to reflected cross-site scripting (XSS) attacks. This could allow an attacker to extract sensitive information by tricking users into accessing a malicious link. |
| CVE-2024-50560 | Low | 2024-11-12 | Not applicable | No public exploit | A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2), SCALANCE MUM853-1 (B1) (6GK5853-2EA10-2BA1) (All versions < V8.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.2), SCALANCE MUM856-1 (A1) (6GK5856-2EA10-3AA1) (All versions < V8.2), SCALANCE MUM856-1 (B1) (6GK5856-2EA10-3BA1) (All versions < V8.2), SCALANCE MUM856-1 (CN) (6GK5856-2EA00-3FA1) (All versions < V8.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices truncates usernames longer than 15 characters when accessed via SSH or Telnet. This could allow an attacker to compromise system integrity. |
| CVE-2024-37995 | Low | 2024-09-10 | Not applicable | No public exploit | A vulnerability has been identified in SIMATIC Reader RF610R CMIIT (6GT2811-6BC10-2AA0) (All versions < V4.2), SIMATIC Reader RF610R ETSI (6GT2811-6BC10-0AA0) (All versions < V4.2), SIMATIC Reader RF610R FCC (6GT2811-6BC10-1AA0) (All versions < V4.2), SIMATIC Reader RF615R CMIIT (6GT2811-6CC10-2AA0) (All versions < V4.2), SIMATIC Reader RF615R ETSI (6GT2811-6CC10-0AA0) (All versions < V4.2), SIMATIC Reader RF615R FCC (6GT2811-6CC10-1AA0) (All versions < V4.2), SIMATIC Reader RF650R ARIB (6GT2811-6AB20-4AA0) (All versions < V4.2), SIMATIC Reader RF650R CMIIT (6GT2811-6AB20-2AA0) (All versions < V4.2), SIMATIC Reader RF650R ETSI (6GT2811-6AB20-0AA0) (All versions < V4.2), SIMATIC Reader RF650R FCC (6GT2811-6AB20-1AA0) (All versions < V4.2), SIMATIC Reader RF680R ARIB (6GT2811-6AA10-4AA0) (All versions < V4.2), SIMATIC Reader RF680R CMIIT (6GT2811-6AA10-2AA0) (All versions < V4.2), SIMATIC Reader RF680R ETSI (6GT2811-6AA10-0AA0) (All versions < V4.2), SIMATIC Reader RF680R FCC (6GT2811-6AA10-1AA0) (All versions < V4.2), SIMATIC Reader RF685R ARIB (6GT2811-6CA10-4AA0) (All versions < V4.2), SIMATIC Reader RF685R CMIIT (6GT2811-6CA10-2AA0) (All versions < V4.2), SIMATIC Reader RF685R ETSI (6GT2811-6CA10-0AA0) (All versions < V4.2), SIMATIC Reader RF685R FCC (6GT2811-6CA10-1AA0) (All versions < V4.2), SIMATIC RF1140R (6GT2831-6CB00) (All versions < V1.1), SIMATIC RF1170R (6GT2831-6BB00) (All versions < V1.1), SIMATIC RF166C (6GT2002-0EE20) (All versions < V2.2), SIMATIC RF185C (6GT2002-0JE10) (All versions < V2.2), SIMATIC RF186C (6GT2002-0JE20) (All versions < V2.2), SIMATIC RF186CI (6GT2002-0JE50) (All versions < V2.2), SIMATIC RF188C (6GT2002-0JE40) (All versions < V2.2), SIMATIC RF188CI (6GT2002-0JE60) (All versions < V2.2), SIMATIC RF360R (6GT2801-5BA30) (All versions < V2.2). The affected application improperly handles error while a faulty certificate upload leading to crashing of application. This vulnerability could allow an attacker to disclose sensitive information. |
| CVE-2024-41907 | Low | 2024-08-13 | Not applicable | No public exploit | A vulnerability has been identified in SINEC Traffic Analyzer (6GK8822-1BG01-0BA0) (All versions < V2.0). The affected application is missing general HTTP security headers in the web server. This could allow an attacker to make the servers more prone to clickjacking attack. |
| CVE-2023-48430 | Low | 2023-12-12 | Not applicable | No public exploit | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The REST API of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the API. The server will automatically restart. |
| CVE-2023-48429 | Low | 2023-12-12 | Not applicable | No public exploit | A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 2). The Web UI of affected devices does not check the length of parameters in certain conditions. This allows a malicious admin to crash the server by sending a crafted request to the server. The server will automatically restart. |
| CVE-2023-40732 | Low | 2023-09-12 | Not applicable | No public exploit | A vulnerability has been identified in QMS Automotive (All versions < V12.39). The QMS.Mobile module of the affected application does not invalidate the session token on logout. This could allow an attacker to perform session hijacking attacks. |
| CVE-2023-38524 | Low | 2023-08-08 | Not applicable | No public exploit | A vulnerability has been identified in Parasolid V34.1 (All versions < V34.1.258), Parasolid V35.0 (All versions < V35.0.254), Parasolid V35.1 (All versions < V35.1.171), Teamcenter Visualization V14.1 (All versions < V14.1.0.11), Teamcenter Visualization V14.2 (All versions < V14.2.0.6), Teamcenter Visualization V14.3 (All versions < V14.3.0.3). The affected applications contain null pointer dereference while parsing specially crafted X_T files. This could allow an attacker to execute code in the context of the current process. |
| CVE-2023-29128 | Low | 2023-05-09 | Not applicable | No public exploit | A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The filename in the upload feature of the web based management of the affected device is susceptible to a path traversal vulnerability. This could allow an authenticated privileged remote attacker to write any file with the extension `.db`. |
| CVE-2023-27410 | Low | 2023-05-09 | Not applicable | No public exploit | A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A heap-based buffer overflow vulnerability was found in the `edgebox_web_app` binary. The binary will crash if supplied with a backup password longer than 255 characters. This could allow an authenticated privileged attacker to cause a denial of service. |
| CVE-2023-27409 | Low | 2023-05-09 | Not applicable | No public exploit | A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). A path traversal vulnerability was found in the `deviceinfo` binary via the `mac` parameter. This could allow an authenticated attacker with access to the SSH interface on the affected device to read the contents of any file named `address`. |
| CVE-2023-27408 | Low | 2023-05-09 | Not applicable | No public exploit | A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The `i2c` mutex file is created with the permissions bits of `-rw-rw-rw-`. This file is used as a mutex for multiple applications interacting with i2c. This could allow an authenticated attacker with access to the SSH interface on the affected device to interfere with the integrity of the mutex and the data it protects. |
| CVE-2021-44448 | Low | 2021-12-14 | Not applicable | No public exploit | A vulnerability has been identified in JT Utilities (All versions < V13.0.3.0), JTTK (All versions < V11.0.3.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14843, ZDI-CAN-15051) |
| CVE-2021-44444 | Low | 2021-12-14 | Not applicable | No public exploit | A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-15052) |
| CVE-2021-44436 | Low | 2021-12-14 | Not applicable | No public exploit | A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14905) |
| CVE-2021-44431 | Low | 2021-12-14 | Not applicable | No public exploit | A vulnerability has been identified in JT Utilities (All versions < V13.1.1.0), JTTK (All versions < V11.1.1.0). JTTK library in affected products is vulnerable to an out of bounds read past the end of an allocated buffer when parsing specially crafted JT files. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14841) |
| CVE-2021-41538 | Low | 2021-09-28 | Not applicable | No public exploit | A vulnerability has been identified in NX 1953 Series (All versions < V1973.3700), NX 1980 Series (All versions < V1988), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to information disclosure by unexpected access to an uninitialized pointer while parsing user-supplied OBJ files. An attacker could leverage this vulnerability to leak information from unexpected memory locations (ZDI-CAN-13770). |
| CVE-2021-41534 | Low | 2021-09-28 | Not applicable | No public exploit | A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13703). |
| CVE-2021-41533 | Low | 2021-09-28 | Not applicable | No public exploit | A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The affected application is vulnerable to an out of bounds read past the end of an allocated buffer when parsing JT files. An attacker could leverage this vulnerability to leak information in the context of the current process (ZDI-CAN-13565). |
| CVE-2021-37176 | Low | 2021-09-14 | Not applicable | No public exploit | A vulnerability has been identified in Simcenter Femap V2020.2 (All versions), Simcenter Femap V2021.1 (All versions). The femap.exe application lacks proper validation of user-supplied data when parsing modfem files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-14260) |
| CVE-2021-33738 | Low | 2021-08-10 | Not applicable | No public exploit | A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405) |
| CVE-2021-22924 | Low | 2021-08-05 | Not applicable | Proof of concept only | libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate. |
| CVE-2021-22898 | Low | 2021-06-11 | Not applicable | Proof of concept only | curl 7.7 through 7.76.1 suffers from an information disclosure when the `-t` command line option, known as `CURLOPT_TELNETOPTIONS` in libcurl, is used to send variable=content pairs to TELNET servers. Due to a flaw in the option parser for sending NEW_ENV variables, libcurl could be made to pass on uninitialized data from a stack based buffer to the server, resulting in potentially revealing sensitive internal information to the server using a clear-text network protocol. |
| CVE-2020-24588 | Low | 2021-05-11 | Not applicable | No public exploit | The 802.11 standard that underpins Wi-Fi Protected Access (WPA, WPA2, and WPA3) and Wired Equivalent Privacy (WEP) doesn't require that the A-MSDU flag in the plaintext QoS header field is authenticated. Against devices that support receiving non-SSP A-MSDU frames (which is mandatory as part of 802.11n), an adversary can abuse this to inject arbitrary network packets. |
| CVE-2021-23839 | Low | 2021-02-16 | Outside Waratek scope | No public exploit | OpenSSL 1.0.2 supports SSLv2. If a client attempts to negotiate SSLv2 with a server that is configured to support both SSLv2 and more recent SSL and TLS versions then a check is made for a version rollback attack when unpadding an RSA signature. Clients that support SSL or TLS versions greater than SSLv2 are supposed to use a special form of padding. A server that supports greater than SSLv2 is supposed to reject connection attempts from a client where this special form of padding is present, because this indicates that a version rollback has occurred (i.e. both client and server support greater than SSLv2, and yet this is the version that is being requested). The implementation of this padding check inverted the logic so that the connection attempt is accepted if the padding is present, and rejected if it is absent. This means that such as server will accept a connection if a version rollback attack has occurred. Further the server will erroneously reject a connection if a normal SSLv2 connection attempt is made. Only OpenSSL 1.0.2 servers from version 1.0.2s to 1.0.2x are affected by this issue. In order to be vulnerable a 1.0.2 server must: 1) have configured SSLv2 support at compile time (this is off by default), 2) have configured SSLv2 support at runtime (this is off by default), 3) have configured SSLv2 ciphersuites (these are not in the default ciphersuite list) OpenSSL 1.1.1 does not have SSLv2 support and therefore is not vulnerable to this issue. The underlying error is in the implementation of the RSA_padding_check_SSLv23() function. This also affects the RSA_SSLV23_PADDING padding mode used by various other functions. Although 1.1.1 does not support SSLv2 the RSA_padding_check_SSLv23() function still exists, as does the RSA_SSLV23_PADDING padding mode. Applications that directly call that function or use that padding mode will encounter this issue. However since there is no support for the SSLv2 protocol in 1.1.1 this is considered a bug and not a security issue in that version. OpenSSL 1.0.2 is out of support and no longer receiving public updates. Premium support customers of OpenSSL 1.0.2 should upgrade to 1.0.2y. Other users should upgrade to 1.1.1j. Fixed in OpenSSL 1.0.2y (Affected 1.0.2s-1.0.2x). |
| CVE-2020-8284 | Low | 2020-12-14 | Not applicable | Proof of concept only | A malicious server can use the FTP PASV response to trick curl 7.73.0 and earlier into connecting back to a given IP address and port, and this way potentially make curl extract information about services that are otherwise private and not disclosed, for example doing port scanning and service banner extractions. |
| CVE-2019-13922 | Low | 2019-09-13 | Not applicable | No public exploit | A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0 SP1). An attacker with administrative privileges can obtain the hash of a connected device's password. The security vulnerability could be exploited by an attacker with network access to the SINEMA Remote Connect Server and administrative privileges. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| CVE-2018-11464 | Low | 2018-12-12 | Not applicable | No public exploit | A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known. |
| CVE-2016-7960 | Low | 2016-10-13 | Not applicable | No public exploit | Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors. |
| CVE-2016-5849 | Low | 2016-07-04 | Not applicable | No public exploit | Siemens SICAM PAS through 8.07 allows local users to obtain sensitive configuration information by leveraging database stoppage. |
| CVE-2016-3155 | Low | 2016-03-18 | Not applicable | No public exploit | Siemens APOGEE Insight uses weak permissions for the application folder, which allows local users to obtain sensitive information or modify data via unspecified vectors. |
| CVE-2015-7836 | Low | 2015-10-28 | Not applicable | No public exploit | Siemens RUGGEDCOM ROS before 4.2.1 allows remote attackers to obtain sensitive information by sniffing the network for VLAN data within the padding section of an Ethernet frame. |
| CVE-2015-5084 | Low | 2015-08-03 | Not applicable | No public exploit | The Siemens SIMATIC WinCC Sm@rtClient and Sm@rtClient Lite applications before 01.00.01.00 for Android do not properly store passwords, which allows physically proximate attackers to obtain sensitive information via unspecified vectors. |
| CVE-2015-1602 | Low | 2015-04-06 | Not applicable | No public exploit | Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files. |
| CVE-2015-1599 | Low | 2015-03-07 | Not applicable | No public exploit | The Siemens SPCanywhere application for iOS allows physically proximate attackers to bypass intended access restrictions by leveraging a filesystem architectural error. |
| CVE-2015-1598 | Low | 2015-03-07 | Not applicable | No public exploit | The Siemens SPCanywhere application for Android does not properly store application passwords, which allows physically proximate attackers to obtain sensitive information by examining the device filesystem. |
| CVE-2015-1355 | Low | 2015-02-18 | Not applicable | No public exploit | Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack. |
| CVE-2014-5233 | Low | 2015-01-14 | Not applicable | No public exploit | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to discover Sm@rtServer credentials by leveraging an error in the credential-processing mechanism. |
| CVE-2014-5232 | Low | 2015-01-14 | Not applicable | No public exploit | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows local users to bypass an intended application-password requirement by leveraging the running of the app in the background state. |
| CVE-2014-5231 | Low | 2015-01-14 | Not applicable | No public exploit | The Siemens SIMATIC WinCC Sm@rtClient app before 1.0.2 for iOS allows physically proximate attackers to extract the password from storage via unspecified vectors. |
| CVE-2013-0672 | Low | 2013-03-21 | Not applicable | No public exploit | Cross-site scripting (XSS) vulnerability in the HMI web application in Siemens WinCC (TIA Portal) 11 allows remote authenticated users to inject arbitrary web script or HTML via unspecified data. |
| CVE-2012-4693 | Low | 2012-12-18 | Not applicable | No public exploit | Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file. |
| CVE-2012-4691 | Low | 2012-12-18 | Not applicable | No public exploit | Memory leak in Siemens Automation License Manager (ALM) 4.x and 5.x before 5.2 allows remote attackers to cause a denial of service (memory consumption) via crafted packets. |
| CVE-2004-2626 | Low | 2004-12-31 | Not applicable | Working exploit published | GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message. |
| CVE-2001-0384 | Low | 2001-07-02 | Not applicable | Working exploit published | ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file. |