Overview 12 matches · 0 in Waratek scope · 0 protected · 1 exploited · 0 CISA KEV · 1 public PoC · 1 EPSS ≥ 0.5
12matches
0in Waratek scope0.0%
0protected0.0%
1exploited8.3%
0CISA KEV0.0%
1public PoC8.3%
1EPSS ≥ 0.58.3%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
0
0.0%
Not applicable
12
100.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
12
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
1
8.3%
Working exploit published
0
0.0%
Proof of concept only
0
0.0%
Forecast only
0
0.0%
No public exploit
11
91.7%
split by
peak 5 / year
20172
Not applicable2
Critical2
not blocked2
No public exploit2
20181
Not applicable1
Critical1
not blocked1
No public exploit1
20195
Not applicable5
Critical5
not blocked5
Exploited1
No public exploit4
20201
Not applicable1
Critical1
not blocked1
No public exploit1
20211
Not applicable1
Critical1
not blocked1
No public exploit1
20221
Not applicable1
Critical1
not blocked1
No public exploit1
20230
20240
20250
20261
Not applicable1
Critical1
not blocked1
No public exploit1
2017201820192020202120222023202420252026
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2025-15620 | Critical | 2026-04-02 | Not applicable | No public exploit | HiOS Switch Platform versions 09.1.00 through 09.4.04 and 10.0.00 through 10.3.00 contain a denial-of-service vulnerability in the web interface that allows remote attackers to reboot the affected device by sending a malicious HTTP GET request to a specific endpoint. Attackers can trigger an uncontrolled reboot condition through crafted HTTP requests to cause service disruption and unavailability of the switch. |
| CVE-2021-30064 | Critical | 2022-04-03 | Not applicable | No public exploit | On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can succeed with hardcoded default credentials (if the device is in the uncommissioned state). |
| CVE-2021-27734 | Critical | 2021-05-17 | Not applicable | No public exploit | Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing users. |
| CVE-2020-6994 | Critical | 2020-04-03 | Not applicable | No public exploit | A buffer overflow vulnerability was found in some devices of Hirschmann Automation and Control HiOS and HiSecOS. The vulnerability is due to improper parsing of URL arguments. An attacker could exploit this vulnerability by specially crafting HTTP requests to overflow an internal buffer. The following devices using HiOS Version 07.0.02 and lower are affected: RSP, RSPE, RSPS, RSPL, MSP, EES, EES, EESX, GRS, OS, RED. The following devices using HiSecOS Version 03.2.00 and lower are affected: EAGLE20/30. |
| CVE-2019-12262 | Critical | 2019-08-14 | Not applicable | No public exploit | Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and 7 has Incorrect Access Control in the RARP client component. IPNET security vulnerability: Handling of unsolicited Reverse ARP replies (Logical Flaw). |
| CVE-2019-12261 | Critical | 2019-08-09 | Not applicable | No public exploit | Wind River VxWorks 6.7 though 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 3 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion during connect() to a remote host. |
| CVE-2019-12260 | Critical | 2019-08-09 | Not applicable | No public exploit | Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the TCP component (issue 2 of 4). This is an IPNET security vulnerability: TCP Urgent Pointer state confusion caused by a malformed TCP AO option. |
| CVE-2019-12256 | Critical | 2019-08-09 | Not applicable | No public exploit | Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options. |
| CVE-2019-12255 | Critical | 2019-08-09 | Not applicable | Exploited | Wind River VxWorks has a Buffer Overflow in the TCP component (issue 1 of 4). This is a IPNET security vulnerability: TCP Urgent Pointer = 0 that leads to an integer underflow. |
| CVE-2018-5469 | Critical | 2018-03-06 | Not applicable | No public exploit | An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUS Classic Platform Switches. An improper restriction of excessive authentication vulnerability in the web interface has been identified, which may allow an attacker to brute force authentication. |
| CVE-2017-11402 | Critical | 2017-11-20 | Not applicable | No public exploit | An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Design flaws in OPC classic and in custom netfilter modules allow an attacker to remotely activate rules on the firewall and to connect to any TCP port of a protected asset, thus bypassing the firewall. The attack methodology is a crafted OPC dynamic port shift. |
| CVE-2017-11401 | Critical | 2017-11-20 | Not applicable | No public exploit | An issue has been discovered on the Belden Hirschmann Tofino Xenon Security Appliance before 03.2.00. Improper handling of the mbap.length field of ModBus packets in the ModBus DPI filter allows an attacker to send malformed/crafted packets to a protected asset, bypassing function code filtering. |