Overview 9 matches · 0 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 1 public PoC · 0 EPSS ≥ 0.5
9matches
0in Waratek scope0.0%
0protected0.0%
0exploited0.0%
0CISA KEV0.0%
1public PoC11.1%
0EPSS ≥ 0.50.0%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
8
88.9%
Not applicable
1
11.1%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
9
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
1
11.1%
Proof of concept only
0
0.0%
Forecast only
0
0.0%
No public exploit
8
88.9%
split by
peak 3 / year
20121
Outside Waratek scope1
High1
not blocked1
Working exploit published1
20130
20140
20150
20160
20173
Outside Waratek scope3
High3
not blocked3
No public exploit3
20180
20190
20200
20211
Outside Waratek scope1
High1
not blocked1
No public exploit1
20220
20232
Outside Waratek scope1
Not applicable1
High2
not blocked2
No public exploit2
20240
20252
Outside Waratek scope2
High2
not blocked2
No public exploit2
2013201520172019202120232025
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2025-40772 | High | 2025-10-14 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications are vulnerable to stored Cross-Site Scripting (XSS), allowing an attacker to inject malicious code that can be executed by other users when they visit the affected page. Successful exploitation allows an attacker to impersonate other users within the application and steal their session data. This could enable unauthorized access to accounts and potentially lead to privilege escalation. |
| CVE-2022-31812 | High | 2025-05-23 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SiPass integrated (All versions < V2.95.3.18). Affected server applications contain an out of bounds read past the end of an allocated buffer while checking the integrity of incoming packets. This could allow an unauthenticated remote attacker to create a denial of service condition. |
| CVE-2022-31810 | High | 2023-07-11 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow. This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition. |
| CVE-2022-31808 | High | 2023-02-14 | Not applicable | No public exploit | A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V2.85.44), SiPass integrated ACC-AP (All versions < V2.85.43). Affected devices improperly sanitize user input on the telnet command line interface. This could allow an authenticated user to escalate privileges by injecting arbitrary commands that are executed with root privileges. |
| CVE-2021-44522 | High | 2021-12-14 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SiPass integrated V2.76 (All versions), SiPass integrated V2.80 (All versions), SiPass integrated V2.85 (All versions), Siveillance Identity V1.5 (All versions), Siveillance Identity V1.6 (All versions < V1.6.284.0). Affected applications insufficiently limit the access to the internal message broker system. This could allow an unauthenticated remote attacker to subscribe to arbitrary message queues. |
| CVE-2017-9942 | High | 2017-08-08 | Outside Waratek scope | No public exploit | A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems. |
| CVE-2017-9941 | High | 2017-08-08 | Outside Waratek scope | No public exploit | A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| CVE-2017-9940 | High | 2017-08-08 | Outside Waratek scope | No public exploit | A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network. |
| CVE-2012-5409 | High | 2012-11-01 | Outside Waratek scope | Working exploit published | AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted messages, as demonstrated by an arbitrary pointer dereference attack or a buffer overflow attack. |