Overview 6 matches · 0 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 0 public PoC · 1 EPSS ≥ 0.5
6matches
0in Waratek scope0.0%
0protected0.0%
0exploited0.0%
0CISA KEV0.0%
0public PoC0.0%
1EPSS ≥ 0.516.7%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
3
50.0%
Not applicable
3
50.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
6
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
0
0.0%
Proof of concept only
0
0.0%
Forecast only
1
16.7%
No public exploit
5
83.3%
split by
peak 2 / year
20141
Not applicable1
High1
not blocked1
No public exploit1
20150
20161
Not applicable1
High1
not blocked1
No public exploit1
20170
20180
20191
Not applicable1
High1
not blocked1
No public exploit1
20200
20212
Outside Waratek scope2
High2
not blocked2
Forecast only1
No public exploit1
20221
Outside Waratek scope1
High1
not blocked1
No public exploit1
201420152016201720182019202020212022
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2022-25311 | High | 2022-03-08 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SINEC NMS (All versions >= V1.0.3 < V2.0), SINEC NMS (All versions < V1.0.3), SINEMA Server V14 (All versions). The affected software do not properly check privileges between users during the same web browser session, creating an unintended sphere of control. This could allow an authenticated low privileged user to achieve privilege escalation. |
| CVE-2021-34798 | High | 2021-09-16 | Outside Waratek scope | Forecast only | Malformed requests may cause the server to dereference a NULL pointer. This issue affects Apache HTTP Server 2.4.48 and earlier. |
| CVE-2020-25237 | High | 2021-02-09 | Outside Waratek scope | No public exploit | A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP1 Update 1), SINEMA Server (All versions < V14.0 SP2 Update 2). When uploading files to an affected system using a zip container, the system does not correctly check if the relative file path of the extracted files is still within the intended target directory. With this an attacker could create or overwrite arbitrary files on an affected system. This type of vulnerability is also known as 'Zip-Slip'. (ZDI-CAN-12054) |
| CVE-2019-6575 | High | 2019-04-17 | Not applicable | No public exploit | A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication. |
| CVE-2016-6486 | High | 2016-08-08 | Not applicable | No public exploit | Siemens SINEMA Server uses weak permissions for the application folder, which allows local users to gain privileges via unspecified vectors. |
| CVE-2014-2731 | High | 2014-04-19 | Not applicable | No public exploit | Multiple unspecified vulnerabilities in the integrated web server in Siemens SINEMA Server before 12 SP1 allow remote attackers to execute arbitrary code via HTTP traffic to port (1) 4999 or (2) 80. |