Overview 4 matches · 1 protected · 0 exploited · 0 CISA KEV · 0 public PoC · 0 EPSS ≥ 0.5
Protected by Waratek
1
25.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
3
75.0%
blocked by ARMR today
1
25.0%
partly blocked
0
0.0%
not blocked
3
75.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
0
0.0%
Proof of concept only
0
0.0%
Forecast only
0
0.0%
No public exploit
4
100.0%
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2022-2764 | Medium | 2022-09-01 | No exploit published | No public exploit | A flaw was found in Undertow. Denial of service can be achieved as Undertow server waits for the LAST_CHUNK forever for EJB invocations. |
| CVE-2021-4178 | Medium | 2022-08-24 | Protected by Waratek | No public exploit | A arbitrary code execution flaw was found in the Fabric 8 Kubernetes client affecting versions 5.0.0-beta-1 and above. Due to an improperly configured YAML parsing, this will allow a local and privileged attacker to supply malicious YAML. |
| CVE-2021-3690 | High | 2022-08-23 | No exploit published | No public exploit | A flaw was found in Undertow. A buffer leak on the incoming WebSocket PONG message may lead to memory exhaustion. This flaw allows an attacker to cause a denial of service. The highest threat from this vulnerability is availability. |
| CVE-2022-2053 | High | 2022-08-05 | No exploit published | No public exploit | When a POST request comes through AJP and the request exceeds the max-post-size limit (maxEntitySize), Undertow's AjpServerRequestConduit implementation closes a connection without sending any response to the client/proxy. This behavior results in that a front-end proxy marking the backend worker (application server) as an error state and not forward requests to the worker for a while. In mod_cluster, this continues until the next STATUS request (10 seconds intervals) from the application server updates the server state. So, in the worst case, it can result in "All workers are in error state" and mod_cluster responds "503 Service Unavailable" for a while (up to 10 seconds). In mod_proxy_balancer, it does not forward requests to the worker until the "retry" timeout passes. However, luckily, mod_proxy_balancer has "forcerecovery" setting (On by default; this parameter can force the immediate recovery of all workers without considering the retry parameter of the workers if all workers of a balancer are in error state.). So, unlike mod_cluster, mod_proxy_balancer does not result in responding "503 Service Unavailable". An attacker could use this behavior to send a malicious request and trigger server errors, resulting in DoS (denial of service). This flaw was fixed in Undertow 2.2.19.Final, Undertow 2.3.0.Alpha2. |