Overview 21 matches · 0 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 1 public PoC · 0 EPSS ≥ 0.5
21matches
0in Waratek scope0.0%
0protected0.0%
0exploited0.0%
0CISA KEV0.0%
1public PoC4.8%
0EPSS ≥ 0.50.0%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
0
0.0%
Not applicable
21
100.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
21
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
1
4.8%
Proof of concept only
2
9.5%
Forecast only
0
0.0%
No public exploit
18
85.7%
split by
peak 11 / year
20131
Not applicable1
High1
not blocked1
No public exploit1
20140
20152
Not applicable2
High1
Medium1
not blocked2
No public exploit2
20160
20170
20180
20190
202011
Not applicable11
Critical5
High2
Medium3
Low1
not blocked11
No public exploit11
20210
20220
20231
Not applicable1
High1
not blocked1
No public exploit1
20243
Not applicable3
Critical1
High1
Medium1
not blocked3
Working exploit published1
Proof of concept only2
20253
Not applicable3
Medium3
not blocked3
No public exploit3
2013201520172019202120232025
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2025-27955 | Medium | 2025-06-02 | Not applicable | No public exploit | Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code. |
| CVE-2025-27954 | Medium | 2025-06-02 | Not applicable | No public exploit | An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx. |
| CVE-2025-27953 | Medium | 2025-06-02 | Not applicable | No public exploit | An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component. |
| CVE-2024-4654 | Critical | 2024-05-08 | Not applicable | Proof of concept only | A vulnerability was found in BlueNet Technology Clinical Browsing System 1.2.1. It has been classified as critical. This affects an unknown part of the file /xds/cloudInterface.php. The manipulation of the argument INSTI_CODE leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263499. |
| CVE-2024-4653 | High | 2024-05-08 | Not applicable | Proof of concept only | A vulnerability was found in BlueNet Technology Clinical Browsing System 1.2.1 and classified as critical. Affected by this issue is some unknown functionality of the file /xds/outIndex.php. The manipulation of the argument name leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-263498 is the identifier assigned to this vulnerability. |
| CVE-2024-4257 | Medium | 2024-04-27 | Not applicable | Working exploit published | A vulnerability was found in BlueNet Technology Clinical Browsing System 1.2.1. It has been classified as critical. This affects an unknown part of the file /xds/deleteStudy.php. The manipulation of the argument documentUniqueId leads to sql injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262149 was assigned to this vulnerability. |
| CVE-2023-22377 | High | 2023-02-15 | Not applicable | No public exploit | Improper restriction of XML external entity reference (XXE) vulnerability exists in tsClinical Define.xml Generator all versions (v1.0.0 to v1.4.0) and tsClinical Metadata Desktop Tools Version 1.0.3 to Version 1.1.0. If this vulnerability is exploited, an attacker may obtain an arbitrary file which meets a certain condition by reading a specially crafted XML file. |
| CVE-2020-16247 | High | 2020-09-18 | Not applicable | No public exploit | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. |
| CVE-2020-16200 | Medium | 2020-09-18 | Not applicable | No public exploit | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources. |
| CVE-2020-16198 | Medium | 2020-09-18 | Not applicable | No public exploit | When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct. |
| CVE-2020-14525 | Low | 2020-09-18 | Not applicable | No public exploit | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users. |
| CVE-2020-14506 | Medium | 2020-09-18 | Not applicable | No public exploit | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. |
| CVE-2020-6966 | Critical | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilize a weak encryption scheme for remote desktop control, which may allow an attacker to obtain remote code execution of devices on the network. |
| CVE-2020-6965 | Critical | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, a vulnerability in the software update mechanism allows an authenticated attacker to upload arbitrary files on the system through a crafted update package. |
| CVE-2020-6964 | High | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network. |
| CVE-2020-6963 | Critical | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X, the affected products utilized hard coded SMB credentials, which may allow an attacker to remotely execute arbitrary code. |
| CVE-2020-6962 | Critical | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X CARESCAPE Central Station (CSCS) Versions 2.X, B450 Version 2.X, B650 Version 1.X, B650 Version 2.X, B850 Version 1.X, B850 Version 2.X, an input validation vulnerability exists in the web-based system configuration utility that could allow an attacker to obtain arbitrary remote code execution. |
| CVE-2020-6961 | Critical | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server, Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Telemetry Server Version 4.3, CARESCAPE Central Station (CSCS) Versions 1.X, a vulnerability exists in the affected products that could allow an attacker to obtain access to the SSH private key in configuration files. |
| CVE-2014-9736 | High | 2015-08-04 | Not applicable | No public exploit | GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) server keystore; (3) keystore_password for the server truststore; and atna for the (4) primary storage database and (5) archive storage database, which has unspecified impact and attack vectors. |
| CVE-2015-2814 | Medium | 2015-04-01 | Not applicable | No public exploit | SAP EMR Unwired (com.sap.mobile.healthcare.emr.v2) and Clinical Task Tracker (com.sap.mobile.healthcare.ctt) does not properly restrict access, which allows remote attackers to change the backendurl, clientid, ssourl, and infopageurl settings via unspecified vectors, aka SAP Security Note 2117079. |
| CVE-2013-5558 | High | 2013-11-08 | Not applicable | No public exploit | The WIL-A module in Cisco TelePresence VX Clinical Assistant 1.2 before 1.21 changes the admin password to an empty password upon a reboot, which makes it easier for remote attackers to obtain access via the administrative interface, aka Bug ID CSCuj17238. |