Overview 8 matches · 2 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 0 public PoC · 0 EPSS ≥ 0.5
8matches
2in Waratek scope25.0%
0protected0.0%
0exploited0.0%
0CISA KEV0.0%
0public PoC0.0%
0EPSS ≥ 0.50.0%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
2
25.0%
Outside Waratek scope
0
0.0%
Not applicable
6
75.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
8
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
0
0.0%
Working exploit published
0
0.0%
Proof of concept only
1
12.5%
Forecast only
0
0.0%
No public exploit
7
87.5%
split by
peak 2 / year
20051
No exploit published1
High1
not blocked1
No public exploit1
20060
20070
20080
20090
20100
20110
20120
20131
Not applicable1
High1
not blocked1
No public exploit1
20140
20151
Not applicable1
High1
not blocked1
No public exploit1
20160
20170
20180
20190
20202
Not applicable2
High2
not blocked2
No public exploit2
20211
No exploit published1
High1
not blocked1
No public exploit1
20220
20231
Not applicable1
High1
not blocked1
No public exploit1
20241
Not applicable1
High1
not blocked1
Proof of concept only1
2006200820102012201420162018202020222024
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2024-4653 | High | 2024-05-08 | Not applicable | Proof of concept only | A vulnerability was found in BlueNet Technology Clinical Browsing System 1.2.1 and classified as critical. Affected by this issue is some unknown functionality of the file /xds/outIndex.php. The manipulation of the argument name leads to sql injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-263498 is the identifier assigned to this vulnerability. |
| CVE-2023-22377 | High | 2023-02-15 | Not applicable | No public exploit | Improper restriction of XML external entity reference (XXE) vulnerability exists in tsClinical Define.xml Generator all versions (v1.0.0 to v1.4.0) and tsClinical Metadata Desktop Tools Version 1.0.3 to Version 1.1.0. If this vulnerability is exploited, an attacker may obtain an arbitrary file which meets a certain condition by reading a specially crafted XML file. |
| CVE-2021-2351 | High | 2021-07-21 | No exploit published | No public exploit | Vulnerability in the Advanced Networking Option component of Oracle Database Server. Supported versions that are affected are 12.1.0.2, 12.2.0.1 and 19c. Difficult to exploit vulnerability allows unauthenticated attacker with network access via Oracle Net to compromise Advanced Networking Option. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Advanced Networking Option, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in takeover of Advanced Networking Option. Note: The July 2021 Critical Patch Update introduces a number of Native Network Encryption changes to deal with vulnerability CVE-2021-2351 and prevent the use of weaker ciphers. Customers should review: "Changes in Native Network Encryption with the July 2021 Critical Patch Update" (Doc ID 2791571.1). CVSS 3.1 Base Score 8.3 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H). |
| CVE-2020-16247 | High | 2020-09-18 | Not applicable | No public exploit | Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. |
| CVE-2020-6964 | High | 2020-01-24 | Not applicable | No public exploit | In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network. |
| CVE-2014-9736 | High | 2015-08-04 | Not applicable | No public exploit | GE Healthcare Centricity Clinical Archive Audit Trail Repository has a default password of initinit for the (1) SSL key manager and (2) server keystore; (3) keystore_password for the server truststore; and atna for the (4) primary storage database and (5) archive storage database, which has unspecified impact and attack vectors. |
| CVE-2013-5558 | High | 2013-11-08 | Not applicable | No public exploit | The WIL-A module in Cisco TelePresence VX Clinical Assistant 1.2 before 1.21 changes the admin password to an empty password upon a reboot, which makes it easier for remote attackers to obtain access via the administrative interface, aka Bug ID CSCuj17238. |
| CVE-2005-3459 | High | 2005-11-02 | No exploit published | No public exploit | Unspecified vulnerability in Oracle E-Business Suite and Applications 4.5 up to 4.5.1 has unknown impact and attack vectors, as identified by Oracle Vuln# APPS22 in Oracle Clinical. |