Overview 4 matches · 0 in Waratek scope · 0 protected · 1 exploited · 0 CISA KEV · 1 public PoC · 1 EPSS ≥ 0.5
4matches
0in Waratek scope0.0%
0protected0.0%
1exploited25.0%
0CISA KEV0.0%
1public PoC25.0%
1EPSS ≥ 0.525.0%
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
0
0.0%
Not applicable
4
100.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
4
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
1
25.0%
Working exploit published
0
0.0%
Proof of concept only
0
0.0%
Forecast only
0
0.0%
No public exploit
3
75.0%
split by
peak 1 / quarter
Q3 191
Not applicable1
Critical1
not blocked1
No public exploit1
Q4 190
Q1 200
Q2 200
Q3 201
Not applicable1
High1
not blocked1
No public exploit1
Q4 200
Q1 210
Q2 210
Q3 210
Q4 210
Q1 220
Q2 221
Not applicable1
Critical1
not blocked1
No public exploit1
Q3 220
Q4 220
Q1 230
Q2 230
Q3 230
Q4 230
Q1 240
Q2 240
Q3 241
Not applicable1
High1
not blocked1
Exploited1
Q3 19Q1 20Q3 20Q1 21Q3 21Q1 22Q3 22Q1 23Q3 23Q1 24Q3 24
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2024-6387 | High | 2024-07-01 | Not applicable | Exploited | A security regression (CVE-2006-5051) was discovered in OpenSSH's server (sshd). There is a race condition which can lead sshd to handle some signals in an unsafe manner. An unauthenticated, remote attacker may be able to trigger it by failing to authenticate within a set time period. |
| CVE-2022-27577 | Critical | 2022-04-11 | Not applicable | No public exploit | The vulnerability in the MSC800 in all versions before 4.15 allows for an attacker to predict the TCP initial sequence number. When the TCP sequence is predictable, an attacker can send packets that are forged to appear to come from a trusted computer. These forged packets could compromise services on the MSC800. SICK has released a new firmware version of the SICK MSC800 and recommends updating to the newest version. |
| CVE-2020-2075 | High | 2020-08-31 | Not applicable | No public exploit | Platform mechanism AutoIP allows remote attackers to reboot the device via a crafted packet in SICK AG solutions Bulkscan LMS111, Bulkscan LMS511, CLV62x – CLV65x, ICR890-3, LMS10x, LMS11x, LMS15x, LMS12x, LMS13x, LMS14x, LMS5xx, LMS53x, MSC800, RFH. |
| CVE-2019-10979 | Critical | 2019-07-01 | Not applicable | No public exploit | SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password. |