Overview 20 matches · 0 in Waratek scope · 0 protected · 6 exploited · 1 CISA KEV · 3 EPSS ≥ 0.5
20matches 0in Waratek scope0.0% 0protected0.0% 6exploited30.0% 1CISA KEV5.0% 3EPSS ≥ 0.515.0%
20 matches Sign in to download these CVEs as CSV or JSON, or to follow them in a feed.
CVE Severity Published▾ Status Exploitation Description
CVE-2022-34753 High 2022-07-13 Not applicable Exploited A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior)
CVE-2021-22707 Critical 2021-07-21 Not applicable Exploited A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.
CVE-2019-6814 Critical 2019-05-22 Not applicable Exploited A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI.
CVE-2018-7841 Critical 2019-05-22 Not applicable Exploited A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.
CVE-2018-7777 High 2018-07-03 Not applicable Working exploit published The vulnerability is due to insufficient handling of update_file request parameter on update_module.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. A remote, authenticated attacker can exploit this vulnerability by sending a crafted request to the target server.
CVE-2018-7765 High 2018-07-03 Not applicable Exploited The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter.
CVE-2018-1124 High 2018-05-23 Not applicable Working exploit published procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-3639 Medium 2018-05-22 Outside Waratek scope Exploited Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4.
CVE-2017-9965 Medium 2018-01-02 Not applicable Working exploit published An exposure of sensitive information vulnerability exists in Schneider Electric's Pelco VideoXpert Enterprise versions 2.0 and prior. Using a directory traversal attack, an unauthorized person can view web server files.
CVE-2017-6026 Critical 2017-06-30 Not applicable Working exploit published A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by the web application are lacking randomization and are shared between several users. This may allow a current session to be compromised.
CVE-2017-6019 High 2017-04-07 Not applicable Working exploit published An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
CVE-2016-5809 High 2017-02-13 Not applicable Working exploit published An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
CVE-2016-2278 High 2016-03-02 Not applicable Working exploit published Schneider Electric Struxureware Building Operations Automation Server AS 1.7 and earlier and AS-P 1.7 and earlier allows remote authenticated administrators to execute arbitrary OS commands by defeating an msh (aka Minimal Shell) protection mechanism.
CVE-2013-0662 High 2014-04-01 Not applicable Working exploit published Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header.
CVE-2013-3075 High 2013-04-19 Not applicable Working exploit published Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.
CVE-2013-0663 Medium 2013-04-04 Not applicable Working exploit published Cross-site request forgery (CSRF) vulnerability on the Schneider Electric Quantum 140NOE77111, 140NOE77101, and 140NWM10000; M340 BMXNOC0401, BMXNOE0100x, and BMXNOE011xx; and Premium TSXETY4103, TSXETY5103, and TSXWMY100 PLC modules allows remote attackers to hijack the authentication of arbitrary users for requests that execute commands, as demonstrated by modifying HTTP credentials.
CVE-2013-0658 High 2013-02-15 Not applicable Working exploit published Heap-based buffer overflow in RFManagerService.exe in Schneider Electric Accutech Manager 2.00.1 and earlier allows remote attackers to execute arbitrary code via a crafted HTTP request.
CVE-2013-0657 High 2013-01-21 Not applicable Working exploit published Stack-based buffer overflow in Schneider Electric Interactive Graphical SCADA System (IGSS) 10 and earlier allows remote attackers to execute arbitrary code by sending TCP port-12397 data that does not comply with a protocol.
CVE-2012-1990 Medium 2012-05-22 Not applicable Working exploit published Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric Kerweb before 3.0.1 and Kerwin before 6.0.1 allow remote attackers to inject arbitrary web script or HTML via (1) the evtvariablename parameter in an evts.xml action to kw.dll, (2) unspecified search fields, or (3) unspecified content-display fields.
CVE-2011-4034 High 2011-12-02 Not applicable Working exploit published Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.