WaratekVRT Sign in
Reset
More filters (1)
Columns
Including CVEs outside Waratek scope✕Vendor siemens✕
Overview 37 matches · 0 in Waratek scope · 0 protected · 0 exploited · 0 CISA KEV · 5 EPSS ≥ 0.5
37matches 0in Waratek scope0.0% 0protected0.0% 0exploited0.0% 0CISA KEV0.0% 5EPSS ≥ 0.513.5%
Protected by Waratek 0 0.0% Rule in development 0 0.0% Mitigation candidate 0 0.0% No exploit published 0 0.0% Outside Waratek scope 4 10.8% Not applicable 33 89.2% Withdrawn CVE 0 0.0%
blocked by ARMR today 0 0.0% partly blocked 0 0.0% not blocked 37 100.0% not established 0 0.0% unrecorded 0 0.0%
Exploited 0 0.0% Working exploit published 37 100.0% Proof of concept only 0 0.0% Forecast only 0 0.0% No public exploit 0 0.0%
37 matches Sign in to download these CVEs as CSV or JSON, or to follow them in a feed.
CVE Severity Published▾ Status Exploitation Description
CVE-2025-6965 High 2025-07-15 Not applicable Working exploit published There exists a vulnerability in SQLite versions before 3.50.2 where the number of aggregate terms could exceed the number of columns available. This could lead to a memory corruption issue. We recommend upgrading to version 3.50.2 or above.
CVE-2022-23102 Medium 2022-02-09 Not applicable Working exploit published A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V2.0). Affected products contain an open redirect vulnerability. An attacker could trick a valid authenticated user to the device into clicking a malicious link there by leading to phishing attacks.
CVE-2021-25162 High 2021-03-30 Not applicable Working exploit published A remote execution of arbitrary commands vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25161 Medium 2021-03-30 Not applicable Working exploit published A remote cross-site scripting (xss) vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25160 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25159 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25158 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.7 and below; Aruba Instant 8.7.x: 8.7.1.1 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25157 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary file read vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.6 and below; Aruba Instant 8.7.x: 8.7.1.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25156 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary directory create vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.6 and below; Aruba Instant 8.7.x: 8.7.1.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2021-25155 Medium 2021-03-30 Not applicable Working exploit published A remote arbitrary file modification vulnerability was discovered in some Aruba Instant Access Point (IAP) products in version(s): Aruba Instant 6.4.x: 6.4.4.8-4.2.4.17 and below; Aruba Instant 6.5.x: 6.5.4.18 and below; Aruba Instant 8.3.x: 8.3.0.14 and below; Aruba Instant 8.5.x: 8.5.0.11 and below; Aruba Instant 8.6.x: 8.6.0.6 and below; Aruba Instant 8.7.x: 8.7.1.0 and below. Aruba has released patches for Aruba Instant that address this security vulnerability.
CVE-2018-15473 Medium 2018-08-17 Outside Waratek scope Working exploit published OpenSSH through 7.7 is prone to a user enumeration vulnerability due to not delaying bailout for an invalid authenticating user until after the packet containing the request has been fully parsed, related to auth2-gss.c, auth2-hostbased.c, and auth2-pubkey.c.
CVE-2017-5715 Medium 2018-01-04 Outside Waratek scope Working exploit published Systems with microprocessors utilizing speculative execution and indirect branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
CVE-2017-14491 Critical 2017-10-04 Not applicable Working exploit published Heap-based buffer overflow in dnsmasq before 2.78 allows remote attackers to cause a denial of service (crash) or execute arbitrary code via a crafted DNS response.
CVE-2015-7855 Medium 2017-08-07 Outside Waratek scope Working exploit published The decodenetnum function in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to cause a denial of service (assertion failure) via a 6 or mode 7 packet containing a long data value.
CVE-2016-3963 Medium 2016-04-08 Not applicable Working exploit published Siemens SCALANCE S613 allows remote attackers to cause a denial of service (web-server outage) via traffic to TCP port 443.
CVE-2015-2177 High 2015-03-07 Not applicable Working exploit published Siemens SIMATIC S7-300 CPU devices allow remote attackers to cause a denial of service (defect-mode transition) via crafted packets on (1) TCP port 102 or (2) Profibus.
CVE-2014-5074 High 2014-08-17 Not applicable Working exploit published Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets.
CVE-2012-5409 High 2012-11-01 Outside Waratek scope Working exploit published AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted messages, as demonstrated by an arbitrary pointer dereference attack or a buffer overflow attack.
CVE-2012-2441 High 2012-04-28 Not applicable Working exploit published RuggedCom Rugged Operating System (ROS) before 3.3 has a factory account with a password derived from the MAC Address field in a banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) SSH or (2) HTTPS session, a different vulnerability than CVE-2012-1803.
CVE-2012-1803 High 2012-04-28 Not applicable Working exploit published RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
CVE-2011-4879 High 2012-02-03 Not applicable Working exploit published miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not properly handle URIs beginning with a 0xfa character, which allows remote attackers to read data from arbitrary memory locations or cause a denial of service (application crash) via a crafted POST request.
CVE-2011-4878 High 2012-02-03 Not applicable Working exploit published Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
CVE-2011-4877 High 2012-02-03 Not applicable Working exploit published HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
CVE-2011-4876 High 2012-02-03 Not applicable Working exploit published Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
CVE-2011-4875 High 2012-02-03 Not applicable Working exploit published Stack-based buffer overflow in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute arbitrary code via vectors related to Unicode strings.
CVE-2011-4532 Medium 2012-01-08 Not applicable Working exploit published Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
CVE-2011-4531 Medium 2012-01-08 Not applicable Working exploit published Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2011-4530 Medium 2012-01-08 Not applicable Working exploit published Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
CVE-2011-4529 High 2012-01-08 Not applicable Working exploit published Multiple buffer overflows in Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allow remote attackers to execute arbitrary code via a long serialid field in an _licensekey command, as demonstrated by the (1) check_licensekey or (2) read_licensekey command.
CVE-2009-3322 High 2009-09-23 Not applicable Working exploit published The Siemens Gigaset SE361 WLAN router allows remote attackers to cause a denial of service (device reboot) via a flood of crafted TCP packets to port 1723.
CVE-2008-7065 High 2009-08-25 Not applicable Working exploit published Siemens C450 IP and C475 IP VoIP devices allow remote attackers to cause a denial of service (disconnected calls and device reboot) via a crafted SIP packet to UDP port 5060.
CVE-2008-6916 High 2009-08-07 Not applicable Working exploit published Siemens SpeedStream 5200 with NetPort Software 1.1 allows remote attackers to bypass authentication via an invalid Host header, possibly involving a trailing dot in the hostname.
CVE-2009-1152 High 2009-03-26 Not applicable Working exploit published Siemens Gigaset SE461 WiMAX router 1.5-BL024.9.6401, and possibly other versions, allows remote attackers to cause a denial of service (device restart and loss of configuration) by connecting to TCP port 53, then closing the connection.
CVE-2004-2626 Low 2004-12-31 Not applicable Working exploit published GUI overlay vulnerability in the Java API in Siemens S55 cellular phones allows remote attackers to send unauthorized SMS messages by overlaying a confirmation message with a malicious message.
CVE-2003-0190 Medium 2003-05-12 Not applicable Working exploit published OpenSSH-portable (OpenSSH) 3.6.1p1 and earlier with PAM support enabled immediately sends an error message when a user does not exist, which allows remote attackers to determine valid usernames via a timing attack.
CVE-2002-1484 Critical 2003-04-22 Not applicable Working exploit published DB4Web server, when configured to use verbose debug messages, allows remote attackers to use DB4Web as a proxy and attempt TCP connections to other systems (port scan) via a request for a URL that specifies the target IP address and port, which produces a connection status in the resulting error message.
CVE-2001-0384 Low 2001-07-02 Not applicable Working exploit published ppd in Reliant Sinix allows local users to corrupt arbitrary files via a symlink attack in the /tmp/ppd.trace file.