Overview 10 matches · 0 in Waratek scope · 0 protected · 1 CISA KEV · 6 public PoC · 3 EPSS ≥ 0.5
Protected by Waratek
0
0.0%
Rule in development
0
0.0%
Mitigation candidate
0
0.0%
No exploit published
0
0.0%
Outside Waratek scope
1
10.0%
Not applicable
9
90.0%
Withdrawn CVE
0
0.0%
blocked by ARMR today
0
0.0%
partly blocked
0
0.0%
not blocked
10
100.0%
not established
0
0.0%
unrecorded
0
0.0%
Exploited
10
100.0%
Working exploit published
0
0.0%
Proof of concept only
0
0.0%
Forecast only
0
0.0%
No public exploit
0
0.0%
split by
peak 3 / quarter
Q3 171
Not applicable1
Critical1
not blocked1
Exploited1
Q4 170
Q1 180
Q2 183
Outside Waratek scope1
Not applicable2
High1
Medium2
not blocked3
Exploited3
Q3 181
Not applicable1
High1
not blocked1
Exploited1
Q4 180
Q1 190
Q2 192
Not applicable2
Critical2
not blocked2
Exploited2
Q3 190
Q4 190
Q1 200
Q2 200
Q3 200
Q4 200
Q1 211
Not applicable1
High1
not blocked1
Exploited1
Q2 210
Q3 211
Not applicable1
Critical1
not blocked1
Exploited1
Q4 210
Q1 220
Q2 220
Q3 221
Not applicable1
High1
not blocked1
Exploited1
Q3 17Q1 18Q3 18Q1 19Q3 19Q1 20Q3 20Q1 21Q3 21Q1 22Q3 22
| CVE | Severity | Published▾ | Status | Exploitation | Description |
|---|---|---|---|---|---|
| CVE-2022-34753 | High | 2022-07-13 | Not applicable | Exploited | A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior) |
| CVE-2021-22707 | Critical | 2021-07-21 | Not applicable | Exploited | A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges. |
| CVE-2021-22713 | High | 2021-03-11 | Not applicable | Exploited | A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot. |
| CVE-2019-6814 | Critical | 2019-05-22 | Not applicable | Exploited | A CWE-287: Improper Authentication vulnerability exists in the NET55XX Encoder with firmware prior to version 2.1.9.7 which could cause impact to confidentiality, integrity, and availability when a remote attacker crafts a malicious request to the encoder webUI. |
| CVE-2018-7841 | Critical | 2019-05-22 | Not applicable | Exploited | A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered. |
| CVE-2018-7765 | High | 2018-07-03 | Not applicable | Exploited | The vulnerability exists within processing of track_import_export.php in Schneider Electric U.motion Builder software versions prior to v1.3.4. The underlying SQLite database query is subject to SQL injection on the object_id input parameter. |
| CVE-2018-3639 | Medium | 2018-05-22 | Outside Waratek scope | Exploited | Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4. |
| CVE-2018-8872 | High | 2018-05-04 | Not applicable | Exploited | In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, system calls read directly from memory addresses within the control program area without any verification. Manipulating this data could allow attacker data to be copied anywhere within memory. |
| CVE-2018-7522 | Medium | 2018-05-04 | Not applicable | Exploited | In Schneider Electric Triconex Tricon MP model 3008 firmware versions 10.0-10.4, when a system call is made, registers are stored to a fixed memory location. Modifying the data in this location could allow attackers to gain supervisor-level access and control system states. |
| CVE-2017-7973 | Critical | 2017-09-26 | Not applicable | Exploited | A SQL injection vulnerability exists in Schneider Electric's U.motion Builder software versions 1.2.1 and prior in which an unauthenticated user can use calls to various paths allowing performance of arbitrary SQL commands against the underlying database. |